Showing posts with label Catalyst OS. Show all posts
Showing posts with label Catalyst OS. Show all posts

Tuesday, October 26, 2010

CatOS: %SYS-3-PORT_OUT_DISCARD flood on disabled switchports

Scenario
Multiple %SYS-3-PORT_OUT_DISCARD syslogs are generated for a switchport which is currently disabled/administratively shutdown.

2010 Jan 04 16:04:10 EST -05:00 %SYS-3-PORT_OUT_DISCARD:Port 4/47 detected 6029 output discard error(s) in last 30 minutes

MySwitch> sh port status 4/47
# = 802.1X Authenticated Port Name.

Port Name Status Vlan Duplex Speed Type
----- -------------------- ---------- ---------- ------ ----------- ------------
4/47 disabled 66 full 100 10/100/1000
MySwitch>

MySwitch> (enable) sh run 4
... [output omitted] ...
#module 4 : 48-port 10/100/1000BaseT Ethernet
set port disable 4/3-48


Explanation
This is due to an identified bug on the CatOS version.

CSCeg24345 - WS-X6748-GE-TX: Tx counters increment on not connected ports

WS-X6748-GE-TX: Tx counters increment on not connected ports On a WS-X6748-GE-TX module in a Catalyst 6500 running CatOS 8.2(2), a port that is not-connected may increment Tx counters as well as ifOutErrors, ifOutDiscards and txCRC

This bug impacts CatOS releases prior to 8.6 and occurs on WS-X6748-GE-TX blades. It is a cosmetic bug and is non-service impacting.

Versions:
  • 1st Found-In: 8.2(2)


  • Fixed-In : 8.4(3.2), 8.4(4), 8.6(0.85)TAL

  • Note that although this is not service-impacting, it may wreck havoc on your monitoring system, as it will generate one syslog for each disabled port every thirty minutes.

    Wednesday, November 11, 2009

    CatOS : SYS-2-MOD_TEMPSENSORFAIL flood from X6148A-GE-45AF

    CSCsl37513
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCsl37513

    SYS-2-MOD_TEMPSENSORFAIL:Module w/ X6148A-GE-45AF and CatOS

    Symptom:
    Numerous WS-X6148 linecards generate the following error:
    %SYS-2-MOD_TEMPSENSORFAIL:Module # temperature sensors failed, please %powercycle the module


    Conditions:
    No production impact related to this message.

    Workaround:
    Powercycle module as requested by the error message.
    • set module power down module_number
    • set module power up module_number

    Permanent Fix:
    Upgrade IOS/CatOS to the below versions or later:
    8.7(0.22)FW124
    8.7(1.62)LAR
    8.6(5.7)
    8.7(0.22)BUB48
    12.2(33.3.13)SXH
    12.2(33)SXH4

    Wednesday, April 15, 2009

    CATOS: %SYS-3-PKTBUFFERFAIL_ERRDIS: Packet buffer failure detected.

    %%SYS-3-PKTBUFFERFAIL_ERRDIS: Packet buffer failure detected. Err-disabling port [dec]/[dec]

    Description:

    This message indicates that the default error-detection packet buffer setting is error disabling the port. Whenever a parity failure is detected on the port, ASIC ports are error disabled. [dec]/[dec] is the module number/port number of the error-disabled port.

    Recommended Action:

    Power cycle the switching module with the error-disabled port. Note The next message appears as four lines.

    Example:
    2009 Mar 19 22:19:18 GMT +00:00 %SYS-3-PKTBUFFERFAIL_ERRDIS:Packet buffer failure detected. Err-disabling port 12/11.
    2009 Mar 19 22:19:19 GMT +00:00 %SYS-3-PKTBUFFERFAIL_ERRDIS:Packet buffer failure detected. Err-disabling port 12/12.




    MySwitch (enable) show port errdisable-timeout 12/12
    Module 12 is not a Komodo+ Firewall
    Module 12 is not a Venus SLB

    Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
    ---- ---------- ------------------- ---------------------- -----------------
    12/12 errdisable packet-buffer-error Enable No Change
    MySwitch (enable)




    MySwitch (enable) show port errdisable-timeout 12/11
    Module 12 is not a Komodo+ Firewall
    Module 12 is not a Venus SLB

    Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
    ---- ---------- ------------------- ---------------------- -----------------
    12/11 errdisable packet-buffer-error Enable No Change
    MySwitch (enable)




    MySwitch (enable) sh port status 12
    Port Name Status Vlan Duplex Speed Type
    ----- -------------------- ---------- ---------- ------ ----- ------------
    12/1 FOLPT1412 connected 562 full 100 10/100BaseTX
    12/2 FOLPT1413 connected 562 full 100 10/100BaseTX
    12/3 3/6 splpw232131 errdisable 562 full 100 10/100BaseTX
    12/4 ldnpsmeg025 errdisable 565 full 100 10/100BaseTX
    12/5 LDNPSM14006 errdisable 565 full 100 10/100BaseTX
    12/6 LDNPSM14007 errdisable 565 full 100 10/100BaseTX
    12/7 LDNPSM14008 errdisable 565 full 100 10/100BaseTX
    12/8 LDNPSM02989 errdisable 565 full 100 10/100BaseTX
    12/9 LDNPSM14015 errdisable 565 full 100 10/100BaseTX
    12/10 LDNPSM14014 errdisable 565 full 100 10/100BaseTX
    12/11 LDNPSM14012 errdisable 565 full 100 10/100BaseTX
    12/12 lsc42n02-app2 errdisable 562 full 100 10/100BaseTX


    MySwitch (enable) show port errdisable-timeout 12/3
    Module 12 is not a Komodo+ Firewall
    Module 12 is not a Venus SLB

    Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
    ---- ---------- ------------------- ---------------------- -----------------
    12/3 errdisable packet-buffer-error Enable No Change
    MySwitch (enable)





    Example:Resolution:

    set module power down 12
    set module power up 12



    Related document:

    Best Practices for Catalyst 4500/4000, 5500/5000, and 6500/6000 Series Switches Running CatOS Configuration and Management