Showing posts with label err-disable. Show all posts
Showing posts with label err-disable. Show all posts

Monday, January 4, 2010

IOS: %ETHCNTR-3-LOOP_BACK_DETECTED : Keepalive packet loop-back detected on [chars]

Scenario
The switch reports this error message, and the port is forced to linkdown:
%ETHCNTR-3-LOOP_BACK_DETECTED : Keepalive packet loop-back detected on [chars]

Oct 2 10:40:13: %ETHCNTR-3-LOOP_BACK_DETECTED: Keepalive packet loop-back detected on GigabitEthernet0/1
Oct 2 10:40:13: %PM-4-ERR_DISABLE: loopback error detected on Gi0/1, putting Gi0/1 in err-disable state


Description
The problem occurs because the keepalive packet is looped back to the port that sent the keepalive. Keepalives are sent on the Catalyst switches in order to prevent loops in the network. Keepalives are enabled by default on all interfaces. You see this problem on the device that detects and breaks the loop, but not on the device that causes the loop.

Workaround
Issue the no keepalive interface command in order to disable keepalives. A disablement of the keepalive prevents errdisablement of the interface, but it does not remove the loop.

Permanent Fix
In Cisco IOS Software Release 12.2(x)SE-based releases and later, keepalives are not sent on fiber and uplink interfaces by default. Upgrading the IOS version to this or later images should prevent the above issue in the first place.

Wednesday, April 15, 2009

CATOS: %SYS-3-PKTBUFFERFAIL_ERRDIS: Packet buffer failure detected.

%%SYS-3-PKTBUFFERFAIL_ERRDIS: Packet buffer failure detected. Err-disabling port [dec]/[dec]

Description:

This message indicates that the default error-detection packet buffer setting is error disabling the port. Whenever a parity failure is detected on the port, ASIC ports are error disabled. [dec]/[dec] is the module number/port number of the error-disabled port.

Recommended Action:

Power cycle the switching module with the error-disabled port. Note The next message appears as four lines.

Example:
2009 Mar 19 22:19:18 GMT +00:00 %SYS-3-PKTBUFFERFAIL_ERRDIS:Packet buffer failure detected. Err-disabling port 12/11.
2009 Mar 19 22:19:19 GMT +00:00 %SYS-3-PKTBUFFERFAIL_ERRDIS:Packet buffer failure detected. Err-disabling port 12/12.




MySwitch (enable) show port errdisable-timeout 12/12
Module 12 is not a Komodo+ Firewall
Module 12 is not a Venus SLB

Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
---- ---------- ------------------- ---------------------- -----------------
12/12 errdisable packet-buffer-error Enable No Change
MySwitch (enable)




MySwitch (enable) show port errdisable-timeout 12/11
Module 12 is not a Komodo+ Firewall
Module 12 is not a Venus SLB

Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
---- ---------- ------------------- ---------------------- -----------------
12/11 errdisable packet-buffer-error Enable No Change
MySwitch (enable)




MySwitch (enable) sh port status 12
Port Name Status Vlan Duplex Speed Type
----- -------------------- ---------- ---------- ------ ----- ------------
12/1 FOLPT1412 connected 562 full 100 10/100BaseTX
12/2 FOLPT1413 connected 562 full 100 10/100BaseTX
12/3 3/6 splpw232131 errdisable 562 full 100 10/100BaseTX
12/4 ldnpsmeg025 errdisable 565 full 100 10/100BaseTX
12/5 LDNPSM14006 errdisable 565 full 100 10/100BaseTX
12/6 LDNPSM14007 errdisable 565 full 100 10/100BaseTX
12/7 LDNPSM14008 errdisable 565 full 100 10/100BaseTX
12/8 LDNPSM02989 errdisable 565 full 100 10/100BaseTX
12/9 LDNPSM14015 errdisable 565 full 100 10/100BaseTX
12/10 LDNPSM14014 errdisable 565 full 100 10/100BaseTX
12/11 LDNPSM14012 errdisable 565 full 100 10/100BaseTX
12/12 lsc42n02-app2 errdisable 562 full 100 10/100BaseTX


MySwitch (enable) show port errdisable-timeout 12/3
Module 12 is not a Komodo+ Firewall
Module 12 is not a Venus SLB

Port Status ErrDisable Reason Port ErrDisableTimeout Action on Timeout
---- ---------- ------------------- ---------------------- -----------------
12/3 errdisable packet-buffer-error Enable No Change
MySwitch (enable)





Example:Resolution:

set module power down 12
set module power up 12



Related document: